Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J. pediatr. (Rio J.) ; 92(4): 400-408, July-Aug. 2016. tab, graf
Article in English | LILACS | ID: lil-792581

ABSTRACT

Abstract Objective To generate prediction equations for spirometry in 4- to 6-year-old children. Methods Forced vital capacity, forced expiratory volume in 0.5 s, forced expiratory volume in one second, peak expiratory flow, and forced expiratory flow at 25–75% of the forced vital capacity were assessed in 195 healthy children residing in the town of Sete Lagoas, state of Minas Gerais, Southeastern Brazil. The least mean squares method was used to derive the prediction equations. The level of significance was established as p < 0.05. Results Overall, 85% of the children succeeded in performing the spirometric maneuvers. In the prediction equation, height was the single predictor of the spirometric variables as follows: forced vital capacity = exponential [(−2.255) + (0.022 × height)], forced expiratory volume in 0.5 s = exponential [(−2.288) + (0.019 × height)], forced expiratory volume in one second = exponential [(−2.767) + (0.026 × height)], peak expiratory flow = exponential [(−2.908) + (0.019 × height)], and forced expiratory flow at 25–75% of the forced vital capacity = exponential [(−1.404) + (0.016 × height)]. Neither age nor weight influenced the regression equations. No significant differences in the predicted values for boys and girls were observed. Conclusion The predicted values obtained in the present study are comparable to those reported for preschoolers from both Brazil and other countries.


Resumo Objetivo Gerar equações de predição da espirometria em crianças de quatro a seis anos. Métodos Capacidade vital forçada, volume expiratório forçado em 0,5 segundo, volume expiratório forçado em um segundo, pico de fluxo expiratório e fluxo expiratório forçado com 25-75% da capacidade vital forçada foram avaliados em 195 crianças saudáveis que residem em Sete Lagoas, Estado de Minas Gerais, Sudeste do Brasil. O método dos mínimos quadrados foi usado para derivar as equações de predição. O nível de significância foi estabelecido como p < 0,05. Resultados No geral, 85% das crianças foram bem-sucedidas ao fazer as manobras espirométricas. Na equação de predição, a estatura foi a única variável preditora das variáveis espirométricas, da seguinte forma: capacidade vital forçada = exponencial [(-2,255) + (0,022 x estatura)], volume expiratório forçado em 0,5 segundo = exponencial [(-2,288) + (0,019 x estatura)], volume expiratório forçado em um segundo = exponencial [(-2,767) + (0,026 x estatura)], pico do fluxo expiratório = exponencial [(-2,908) + (0,019 x estatura)] e fluxo expiratório forçado com 25-75% da capacidade vital forçada = exponencial [(-1,404) + (0,016 x estatura)]. Nem a idade nem o peso influenciaram as equações de regressão. Não foi observada diferença significativa nos valores previstos em meninos e meninas. Conclusão Os valores previstos obtidos neste estudo são comparáveis àqueles relatados em crianças em idade pré-escolar tanto do Brasil quanto de outros países.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Algorithms , Peak Expiratory Flow Rate/physiology , Vital Capacity/physiology , Forced Expiratory Volume/physiology , Reference Standards , Reference Values , Spirometry/methods , Time Factors , Anthropometry , Predictive Value of Tests , Reproducibility of Results , Analysis of Variance , Age Factors , Statistics, Nonparametric
2.
Rev. méd. Minas Gerais ; 20(3 supl.4): 55-65, out.-dez. 2010. graf
Article in Portuguese | LILACS | ID: biblio-907143

ABSTRACT

Introdução: O principal objetivo da ventilação mecânica é a diminuição do trabalho respiratório. Para que isto ocorra, o ciclo mecânico deveria coincidir com o tempo inspiratório neural do paciente. A assincronia paciente ventilador ocorre por fatores relacionados ao paciente e aos parâmetros ventilatórios e podem prolongar o tempo de suporte mecânico e permanência em unidades de terapia intensiva. Objetivos: Revisar a assincronia nas diferentes fases do ciclo respiratório, sua avaliação através dos gráficos e as intervenções capazes de melhorar a interação paciente ventilador em ventilação por pressão de suporte. Resultados/ Discussão: Através de busca em base de dados científicos, foram incluídos 26 artigos que abordavam o tema proposto. Os diferentes tipos de assincronia podem ser observados através de esforços ineficientes, atrasos no disparo, disparos automáticos, disparos duplos, presença de PEEP intrínseca, términos prematuro ou prolongado da inspiração e curvas diferentes do padrão usual. Conclusão: A correta identificação e ajustes conforme a demanda do paciente são pontos importantes na interação paciente ventilador e podem contribuir para a melhora do prognóstico destes pacientes.(AU)


Introduction: The main reason of mechanical ventilation is the decrease the work of breathing. To achieve it, the mechanical breath should coincide with the neural inspiratory time. Patient-ventilator asynchrony may be secondary for the facts related to the patient´s condition or ventilatory settings and may prolong support and UTI stay. Objectives: Review asynchrony in different phases of mechanical breath, the evaluation through ventilator waveforms and the proper settings to improve patient-ventilator interaction in pressure support ventilation. Results/ Discussion: Through research on scientific basis, 26 studies that match the theme were included. Asynchrony may be seen as inefficient efforts, trigger delay, auto-triggering, double triggering, presence of auto-PEEP, premature termination, delayed termination or unusual waveforms. Conclusion: Proper identification and adjustments that coincides with patient´s demand are critical points in patient ventilator interaction and may contribute to improve their prognosis.(AU)


Subject(s)
Humans , Respiration, Artificial/methods , Ventilators, Mechanical/adverse effects , Interactive Ventilatory Support/methods , Work of Breathing
3.
J. bras. pneumol ; 33(5): 519-526, set.-out. 2007. tab
Article in Portuguese | LILACS | ID: lil-467476

ABSTRACT

OBJETIVO: Avaliar a confiabilidade intra-examinador e inter-examinadores da cirtometria (conjunto de medidas das circunferências de tórax e abdômen durante os movimentos respiratórios) e sua correlação com volumes pulmonares medidos por meio da pletismografia respiratória por indutância. MÉTODOS: Quarenta indivíduos saudáveis, com média de idade de 28 anos, foram avaliados. As medidas foram realizadas em decúbito dorsal em três momentos: em repouso, em inspiração máxima e em expiração máxima. Dois examinadores treinados, os quais foram cegados, realizaram as medidas. Utilizou-se o teste de Friedman para avaliar a confiabilidade intra-examinador e foram utilizados o teste de Wilcoxon e o coeficiente de correlação intraclasse para avaliar a confiabilidade inter-examinadores. A correlação entre os resultados da cirtometria e da pletismografia foi obtida por meio do coeficiente de correlação de Spearman. Para todos os testes, considerou-se um nível de significância estatística de 0,05. RESULTADOS: Os resultados mostraram confiabilidade intra-examinador adequada. Em relação à confiabilidade inter-examinadores, foram observadas diferenças estatisticamente significativas (de no máximo 2,8 cm) em todas os conjuntos de medidas.No entanto, por meio da análise do coeficiente de correlação intraclasse, observou-se que os examinadores foram responsáveis apenas por pequena parte da variabilidade (1,2-5,08 por cento) observada entre as medidas. Quando as medidas da cirtometria foram comparadas aos volumes pulmonares medidos por meio da pletismografia respiratória por indutância, encontraram-se correlações de baixa magnitude (variação de r = 0,170-0,343). CONCLUSÕES: Os resultados deste estudo sugerem que a cirtometria constitui uma medida precisa, mas não acurada, para aferir volumes pulmonares.


ABSTRACT OBJECTIVE: To determine the intrarater and interrater reliability of cirtometry (measurements of the circumference of the chest and abdomen taken during respiratory movements) as well as its correlation with pulmonary volumes measured by respiratory inductive plethysmography. METHODS: A total of 40 healthy individuals were evaluated. The mean age was 28 years. The measurements were taken in the supine position at three different time points: at rest, at maximal inspiration, and at maximal expiration. Two trained investigators, each of whom was blinded as to the results obtained by the other, performed the measurements. The Friedman test was used to determine intrarater reliability, and the Wilcoxon test, together with the intraclass correlation coefficient, were used to determine interrater reliability. The correlation between the cirtometry measurements and the plethysmography results was obtained using Spearman's correlation coefficient. The level of significance was set at 0.05 for all tests. RESULTS: Intrarater reliability was satisfactory. Regarding interrater reliability, statistically significant differences (2.8 cm at the most) were found in all sets of measurements. However, through the analysis of the intraclass correlation coefficient, the investigators were found to be responsible only for a small portion of the variability (1.2-5.08 percent) found among the measurements. When the cirtometry measurements were compared to the volumes measured by respiratory inductive plethysmography, low correlations (range, r = 0.170-0.343) were found. CONCLUSIONS: The findings of this study suggest that, although cirtometry is a reliable measurement, it does not accurately measure pulmonary volumes.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Abdomen/anatomy & histology , Anthropometry/methods , Metric System/standards , Plethysmography/standards , Respiration , Thorax/anatomy & histology , Axilla , Lung Volume Measurements , Metric System/instrumentation , Reproducibility of Results , Rest , Spirometry , Statistics, Nonparametric , Umbilicus , Xiphoid Bone
SELECTION OF CITATIONS
SEARCH DETAIL